6-MAINTENANCE
2.Closethevalveonthesupplylinethenremovethe
electromagneticfeedpump.
75B56E5520
3.Openthepumpbodyandextractthelter(3)andthe
seals(2)and(4).
WARNING
Flyingdebris!
Compressedaircanpropeldirt,rust,etc.into
theair.Weareyeandfaceprotectionwhen
usingcompressedair.
Failuretocomplycouldresultindeathorse-
riousinjury.
W0307A
4.Cleanthelterwithcompressedair.Checkthelter
andreplaceitifnecessary.Replacethesealswithnew
seals.
5.Carefullycleanthebody(5)andthecover(1).Nodirt
mustremaininthesupplypump.
6.Re-assemble,takingcaretoinstallthesealsinthe
correctorderthenre-installthepump.
7.Openthevalveonthesupplyline.
8.Bleedthesystem.See"Replacingthefuellterele-
ment".
EQFU5N-003A21
6-33