37
2.1.11 Vibration
Basic Specifications
The vibration can be set up for five different notifications.
Table 2.21
Notification Vibration Pattern Setting Default
Alarm Default ON or OFF OFF
Warning Default ON or OFF OFF
Bar code scan complete Default ON or OFF OFF
Wireless incoming signal Default ON or OFF OFF
User definition User ON or OFF OFF
Vibration Interval
The vibration interval can be set in two different patterns, the default setting and a user defined
setting.
Table 2.22
Pattern Vibration Interval Remarks
Default “ON for 1 second, OFF for 1 second” x [times] Maximum no. of times; 20
User
definition
“Specified ON period, Specified OFF period” x [times]
Setting range; 1/16 seconds to 16 seconds for ON period,
1/16 seconds to 1 second for OFF period
Maximum no. of times; 20
SysPlayVibrator function of the System Library can be used to control ON/OFF state for each
occasion of the vibration and the vibration interval in user definition.
The functions of the System Library relevant to the “Vibration Interval” are as follows.
SysPlayVibrator
: Turns on the vibration.
SysStopVibrator
: Turns off the vibration.
SysSetVibratorMute
: Sets up “Enable” or “Disable” for all the parameters for the vibration
and individual mutes.
SysGetVibratorMute
: Retrieves statuses of all the parameters for the vibration and individual
mutes.