CASTLE S SERIES CONTROLLER – TECHNICAL OPERATION GUIDE
Parameters
Press ‘8’ to select [8.Param] menu from the System Menu.
This menu item sets the controller System Parameter. When user select this menu, the controller will
step through each of the System Parameters.
The System Parameters are listed as below: -
a. Card Lock-Out Mode
‘ON’ / ‘OFF’ value. When this option is set, the card user will only be allowed 3 invalid access
attempts (Card & Pin Mode and Anti-Passback) after the user will be locked out from the
system. Access will need to be manually granted. User cards that have been locked out can only
be used again after resetting the Lock Out Flag. This is described in the DBASE Menu.
b. Check Expiry
‘ON’ / ‘OFF’ value. When this option is set, the system will check the Expiry Date Setting of the
card that set at the Access Level. The system will not allow the card user to access the door
when the card is EXPIRED.
c. Anti-Passback
‘ON’ / ‘OFF’ value. Anti-Passback is to ensure that if the person swipes at the IN-Reader of the
door to go into the protected area, he/she must swipes at the OUT-Reader of the door to go out
from the protected area. After he/she has swiped out of the protected are, the next valid swipe is
only at the In-Reader of the door.
d. Auto-PIN1 to Auto-PIN10 (Common PIN Setting)
4 digits of number are required to set the Auto-PIN numbers. There is 10 PIN numbers to be set.
All the readers can share these PIN numbers. But the door must set the ‘Use Common PIN
Mode’ to ‘ON’ position.
To disable the PIN number, user can set the PIN number to ‘0000’ or set the PIN TimeZone to
‘00’ (this is describe as below).
e. Auto-PIN1 TimeZone to Auto-PIN10 TimeZone
Set the TimeZone for each Auto-PIN, so that each Auto-PIN can be used within the TimeZone
setting.
To disable the PIN number, user can set the PIN TimeZone to ‘00’.
f. Facility Code
A value of 0000-9999 is allowed. If ‘0000’ is entered, the controller will ignore the facility code
encoded in the user cards. Otherwise, only user cards with the set facility code will be accepted.
The default value is ‘0000’.
CASS TECHNOLOGY SDN BHD(338857-X) 25

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cass Technology CASTLE S SERIES and is the answer not in the manual?

Cass Technology CASTLE S SERIES Specifications

General IconGeneral
BrandCass Technology
ModelCASTLE S SERIES
CategoryController
LanguageEnglish