CASTLE S SERIES CONTROLLER – TECHNICAL OPERATION GUIDE
Chapter 11 – CASTLE-S Reader
Programming During Emergency Mode At The Reader
When the controller is down, the readers will then automatically go into Emergency Mode.
The readers will operate in "stand alone" system. But the features and the security level will
be lesser. Even though, the user can still control the readers instead of Controller. It requires
user to enter the Master PIN for the specify reader at the door. All the transaction would not
be downloaded to controller on this event.
The command are tabulated as below:
Command Description
2 Auto Pin mode ON/OFF
3 Facility Code ON/OFF
4 Lock release time
5 Door open time
10 Security ON/OFF
11 Change Facility Code
12 Change Master Pin
18 Change Emergency Pin
To enter the Programming Mode, user has to key in 6 digit of the Master PIN as the user set
at the Individual Door Setting before the controller is down.
The steps are described below: -
02. Auto-PIN Mode ON/OFF
i. Press * Button
ii. Key in Mater PIN
iii. Press 02
iv. Press 1 to ON or 0 to OFF
04. Lock Release Time
i. Press * Button
ii. Key in Mater PIN
iii. Press 04
iv. Key in Period Of Time (0-15)
10. Security ON/OFF
i. Press * Button
v. Key in Mater PIN
vi. Press 10
vii. Press 1 to ON 0 to OFF
12. Change Master Pin
i. Press * Button
ii. Key in Mater PIN
iii. Press 12
iv. Key In New Master PIN in 6
digits.
03. Facility Code ON/OFF
i. Press * Button
ii. Key in Mater PIN
iii. Press 03
iv. Press 1 to ON or 0 to OFF
05. Door open time
i. Press * Button
ii. Key in Mater PIN
iii. Press 05
iv. Key In Period Of Time (0-30)
11. Change Facility Code
i. Press * Button
ii. Key in Mater PIN
iii. Press 11
iv. Key in the Facility Code
18. Change Emergency Pin
i. Press * Button
ii. Key in Mater PIN
iii. Press 18
iv. Key in the new Emergency PIN no
in 4 digits.
CASS TECHNOLOGY SDN BHD(338857-X) 40