NOTES
ON
SAFETY
DURING
USE
_
Correct
Operation
The
CEIA
CMD
Metal
Detector
is
a
detector
which
can
Бе
used
to
localize
small
or
large
metal
masses.
This
manual
describes
the
ways
of
employing
the
detector.
but
does
not
contain
detailed
information
on
general
precautions
for
specific
applications:
the
operator
must
have
attended
a
specific
course
and
have
been
authorised
to
carry
out
such
work.
The
device
must
only
be
used
by
qualified
personnel.
Before
switching
on
the
detector
or
putting
on
the
headphone,
set
the
volume
to
minimum
and
adjust
it
so
that
the
‘correct
operation’
tone
can
be
heard
clearly.
Carry
out
the
test
with
the
reference
sample
provided
each
time
the
device
is
switched
on.
This
is
to
check
that
the
device
is
operating
correctly.
=:
During
operations,
periodically
test
the
detector's
efficiency
by
checking
the
sensitivity,
using
the
specific
sample
(target)
on
an
area
of
the
soil
which
is
free
of
other
metal
parts.
The
CEIA
CMD
Metal
Detector
can
be
used
on
all
types
of
soil,
even
on
those
with
a
high
metal
content,
The
detection
depth
is
automatically
optimised
according
to
the
soil,
following
the
compensation
procedure,
and
also
depends
on
the
quantity
of
metal
contained
іп
the
target
to
be
detected.
Before
starting
operation,
check
the
detection
depth
after
carrying
out
the
compensation
procedure
on
the
“Metal
Free
Area",
using
the
target
with
the
minimum
metal
content.
After
carrying
out
the
soil
compensation
procedure
check
the
sensitivity
of
the
detector
using
the
specific
sample
(target),
to
be
detected
at
the
desired
detection
distance.
When
moving
over
the
soil,
keep
the
height
as
comstent
as
possible.
Move
forward
not
more
than
half
the
length
of
the
sensitive
part
of
the
search
head.
Pay
attention
to
the
position
of
the
sensitivity
potentiometer,
since
this
modifies
the
detection
Gent
of
the
detector.
Keep
the
sensitivity
at
the
leve:
necessary
to
detect
the
specific
sample
(target).
Replace
the
batteries
as
soon
as
possible
7
he
ios
battery
signal
(double
beep)
is
heard.
Battery
polarity:
insert
the
batteries
according
io
the
diagram
on
the
bottom
of
the
case.
This
document
is
property
of
CEIA
which
reserves
all
rights.
Total
or
partial
copying,
modification
anc
Tisi
=
Soter