68
ORACLE Settings
The ORACLE system comes equipped with a number of
adjustable settings to optimize the user experience as well
as settings that pertain to sample analyses and system
functionality.
Within the Settings folder, there are two sections that are
available to all users:
Sample
System
There are an additional three settings that are only available
to Administrators:
Backup
Tools
Event Viewer
Sample
The sample settings are in place to provide the user with
various options during the run as well as adjust certain
testing parameters to optimize the ORACLE analysis for
specific sample types. While certain settings are applied
system-wide, others are specific to certain samples as
indicated.
Sample Tags – Sample tags can be added to
individual tests as a way to further identify and
group certain samples being analyzed. This is
especially useful on the sample results screen,
where grouping samples by product type may be
desired.
Auto Optimize – Auto Optimize is a system wide
internal process where the ORACLE will
automatically determine if a sample contains low
levels of fat, and optimize the signal to those levels.
This will increase analysis time by approximately 1.5
minutes and has shown to increase repeatability and
accuracy for certain samples.
High Temperature Mode – Some samples will
require a higher temperature for optimal analysis.
Please only activate High Temperature Mode if

Other manuals for CEM ORACLE

Question and Answer IconNeed help?

Do you have a question about the CEM ORACLE and is the answer not in the manual?

CEM ORACLE Specifications

General IconGeneral
BrandCEM
ModelORACLE
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety Precautions

Safety Guidelines and Warnings

System Installation

Unpack System

Instructions for safely removing the ORACLE instrument from its shipping carton and placing it.

Cable Connections

Guidance on connecting various cables between the ORACLE, processor box, and magnet.

System Setup

Procedure for initial system configuration, including import of clone files and diagnostics.

Sample Analysis Procedures

QuikPrep Heater Operation

Overview of the integrated heater for rapid sample conditioning and automatic transfer.

QuikPrep Analysis with SMART 6

Instructions for performing fat analysis using the SMART 6 for sample preparation and drying.

Data Management and Reporting

System Maintenance and Diagnostics

Quality Control and Calibration

Ensuring system functionality via QC tests, calibration, and Certified Reference Materials (CRM).

Magnet Stability and Diagnostics

Tests for magnet stability and running system diagnostics for optimal performance.

System Settings and Configuration

Service and Repair

Coreboard Connectivity Configuration

Steps to configure ORACLE connectivity with the coreboard, including IP address settings.