The device is complete, firmly
installed, and the surface is
clean; the information
displayed is normal, and the
parameters meet the technical
requirements;
The connecting wire and
connector are in good condition,
and the plug and socket are in
good contact.
Air
conditioning
system (high
pressure
The device is firm and works
normally; the filter screen of
the return air hood is clean and
free of dust;
Evaporation fan and
condensation fan operate
without abnormal noise.
The pedal is free of jamming,
and can return to its position
when gently placed;
The free stroke of the
accelerator pedal is within
2~3 mm;
The fastening bolts of the pedal
base plate and the connecting
locking mechanism are firm
and reliable.
Additional
insulation
for each part
The surface of each insulator is
clean and free from looseness
and fragmentation.
Total insulation of high-voltage
electrical equipment is ≥ 5 kΩ/V.