4
Maintenance
139
Maintenance
Items S/N Work content Technical requirements
Horn 14 Check the horn The electric horn connector
is connected reliably, and the
sound of both horns is normal
when the horn switch on the
steering wheel is pressed.
Wiper 15 Check wiper
mechanism
The wiper motor and
connecting rod are installed
firmly, all parts are in good
condition, work normally, rotate
without abnormal noise, and
move without interference.
Vehicle
control unit,
drive motor
controller
16 Cleaning,
inspection
and fastening
All components shall be firmly
installed and the connectors
shall be well connected;
The surface of controller and
insulator is clean;
The connecting wire of each
component shall be firm
without looseness, overheating,
discoloration and deformation
of the sheath; the controller
control function, alarm function
and communication function
are displayed normally on the
instrument;
The information in the controller
is displayed normally without
historical fault information.
Power
battery
17 Check the
insulation
(disconnect the
gas quickly)
and measure
the value with a
1000V megger
(Omega)
Insulation resistance of power
battery system is 20MΩ;
Single box power battery, DC+,
DC -, PE to box and between:
DC1000 V, 50 M Ω; 7-pin
connectors (S+, S -, CC1, CC2,
CC3, A+, A -) are DC500V to the
box, DC+, DC - and each other,
50 MΩ. In rainy days and rainy
seasons, insulation resistance
is 20 MΩ.