page 55 www.centsys.com
GENERAL MAINTENANCESECTION 9
TABLE 4
9.2. D5 SMART Maintenance
Description Frequency Corrective Action
Check for insect
infestations
Every 3 months
Clean and remove any nests that are
settling in and around the motor and
Control Card
Check that the M10
half-nuts are tight on
the foundation plate
bolts
Every 6 months Torque setting 20Nm
Check that there is no
sand build-up inside the
unit
Every 6 months
Remove batteries and lower battery
tray and clear out the sand build-up
Check pinion and rack
engagement
Every 6 months
If the mesh is too loose or the rack is
riding on the pinion, contact an installer
to correct
Check the condition of
the pinion
Every 6 months
If the pinion is excessively worn,
contact an installer to replace
Check the condition of
the override cam lock
Every 6 months Dry lubricate if necessary (graphite)
If used, check the
condition of the theft-
deterrent cage
Every 6 months
Ensure that the device is serving its
purpose
If used, check the
condition of the theft-
deterrent cage lock and
that it operates
Every 6 months Dry lubricate if necessary (graphite)
Check the oil level and
inspect the gearbox for
any oil leaks
Every 6 months
Using the oil dipstick,
top up if necessary with
Centurion Systems (Pty) Ltd
approved oil.
(Section 6 - "Lubrication")
If there are any oil leaks,
contact an installer to evaluate
Before performing any maintenance, ensure that the D5 SMART is
isolated!
Insert a moth ball, which may
help to repel insects, at the
bottom of the gearbox

Table of Contents