NVF5 Series User Manual Chapter 6 Parameter Function Description
3 are same):
Frequence setting%
Max.
Ref. level
Min
. Ref.
Reference V
Min.
Ref. level
Max.Ref.
Figure 6-2-1 AI Curve 1 Setting
The curve 4 is similar as curve 1 ~ 3,most 4 point curve can be set up which can
achieve more flexible correspondence.When setting curve 4, the minimum input voltage,
inflection point 1 voltage, inflection point 2 voltage and maximum voltage of the curve
must be increased in turn.
Min
.
Ref
. level
Setting level%
Inflection
2
Reference
Inflection
1
Reference
Inflection
1
Reference
Max
.
Ref
.
Inflection
2
Reference
Max.
Ref. level
Reference
V
Min.Ref
Figure 6-2-2 AI Curve 4 Setting
Code Name Default Setting Range
F5.37 Curve 4 Min. Reference 0.00V
-10.0V~ F5.39
100.0% is
the scale
percenta
ge of
F0.07-Ma
F5.38
Curve 4 Min. Reference
Setting
0.0%
(-100.0~+100.0)%
F5.39
Curve 4 Break Point 1
Reference
3.00V
F5.37 ~ F5.41
F5.40
Curve 4 Break Point 1
Setting
30.0%
(-100.0~+100.0)%
F5.41
Curve 4 Break Point 2
Reference
6.00V
F5.39 ~ F5.43
- 45 -