NVF5 Series User Manual Chapter 6 Parameter Function Description
K4 K3 K2 K1
FA.31
(-100.0~100.0)%
% is
the
Scale
percent
age of
F0.07-
Max.
Output
Freque
ncy
,
the
running
directio
n is
decide
d by
positiv
e/negti
ve of
the
param
eter,
negtive
means
run
reverse
FA.32
(-100.0~100.0)%
FA.33
(-100.0~100.0)%
FA.34
(-100.0~100.0)%
FA.35
(-100.0~100.0)%
FA.36
(-100.0~100.0)%
FA.37
(-100.0~100.0)%
FA.38
(-100.0~100.0)%
FA.39
(-100.0~100.0)%
FA.40
(-100.0~100.0)%
FA.41
(-100.0~100.0)%
FA.42
(-100.0~100.0)%
FA.43
(-100.0~100.0)%
FA.44
(-100.0~100.0)%
1 1 1 1
FA.45
(-100.0~100.0)%
6.2.6 Simple PLC Main Frequency Setting
When selecting Simple PLC as the main frequency reference, through the setting of
parameter FA.00 to select the operation mode of simple PLC, whether memory the Simple
PLC running step and running frequency or not when power failure or inverter stop:
Code Name Default
Description
FA.00
Running
Mode
Selection
0x0000
0x0000 ~
0x1112
Ones Place:PLC Running Mode
0:Single Cycle then stop
1:Single Cycel then holding
the end valu
2:Continuous cycle
Tens Place:Store when Stop
0:No Store
- 48 -