EQUIPMENT. FAILURE TO DISCONNECT POWER MAY CAUSE INJURY OR DEATH.
Problem Possible Cause Corrective Action
Delivery system will not
run.
No power to the system. Check circuits, fuses, and on-off
switches on the equipment.
Bin level switch has stopped the
system due to lack of feed in the
boot.
Check feed supply and for possi-
ble bridging.
Motor overloaded and stopped. Check for foreign material in the
line. Push the motor reset button.
Safety switch actuated in the
Control Unit (red pilot light will be
lit).
Determine reason for feed pack-
ing in the Control Unit. Feed
level switch out of adjustment?
Motor overloads after
running briefly.
Motor too small. Use recommended size motor for
line length.
Low voltage (motor runs slow
and overheats).
Check line voltage at the motor;
use adequate size wire in cir-
cuits.
Foreign object in the auger
(motor runs, stalls, then auger
spins in reverse).
Check auger line, pull auger to
remove objects.
Motor wired in reverse (motor
runs, stalls, no feed conveyed).
Disconnect power and change
wire connections (direct drive
power unit shaft at rear of motor
turns clockwise).
Boot Anchor tight. Check for Anchor binding.
Wet feed being conveyed or
allowed to stand in auger tubes.
Defective motor (over heats with-
out load).
Clean auger and tubes; avoid
conveying wet feed or empty line
after each feeding. Replace
motor.
Motor runs, but auger
does not turn.
Sheared driver bolt at Control
Unit.
Replace driver bolt.
Broken power unit pinion. Examine pinion on motor shaft;
replace BOTH gear head and
pinion if pinion is damaged.