Remote Operation
8-13
Parameters : <NR2>, valid range: 0.0 ~ 999.9 (unit: ms)
Return Parameters : <NR2>
[SOURce :] CURRent : INRush : INTerval
Description : This command sets the measuring interval of the inrush current
measurement.
Query Syntax : [SOURce :] CURRent : INRush : INTerval?
Parameters : <NR2>, valid range: 0.0 ~ 999.9 (unit: ms)
Return Parameters : <NR2>
[SOURce :] FREQuency [: {CW | IMMediate}]
Description : The command sets the frequency of the output waveform of the
AC source in Hz.
Query Syntax : [SOURce :] FREQuency [: {CW | IMMediate}]?
Parameters : <NR2>, valid range: 15.00 ~ 1000.00 (unit: Hz)
Return Parameters : <NR2>
[SOURce :] FUNCtion : SHAPe
Description : This command specifies the waveform buffer. There are two
buffers for the output of the AC source, so the user must
specify the contents of waveform buffer A or B of the AC
source.
Query Syntax : [SOURce :] FUNCtion : SHAPe?
Parameters : A | B
Return Parameters : A | B
[SOURce :] FUNCtion : SHAPe : A
Description : This command specifies the waveform shape of waveform
buffer A.
Query Syntax : [SOURce :] FUNCtion : SHAPe : A?
Parameters : SINE | SQUA | CSIN | DST<01..30> | USR<01..06>
Return Parameters : SINE | SQUA | CSIN | DST<01..30> | USR<01..06>
[SOURce :] FUNCtion : SHAPe : A : MODE
Description : This command selects the mode of the value for the clipped
sine in waveform buffer A.
Query Syntax : [SOURce :] FUNCtion : SHAPe : A : MODE?
Parameters : AMP | THD
Return Parameters : AMP | THD
[SOURce :] FUNCtion : SHAPe : A : THD
Description : This command sets the percentage of THD at which the clipped
sine clips in waveform buffer A.
Query Syntax : [SOURce :] FUNCtion : SHAPe : A : THD?
Parameters : <NR2>, valid range: 0.0% ~ 43%
Return Parameters : <NR2>
[SOURce :] FUNCtion : SHAPe: A : AMP
Description : This command sets the percentage of peak at which the
clipped sine clips in waveform buffer A.
Query Syntax : [SOURce :] FUNCtion : SHAPe : A : AMP?
Parameters : <NR2>, valid range: 0.0% ~ 100%
Return Parameters : <NR2>