Digital Power Meter 66200 Series User’s Manual
Example 2:
Query: FETC?<space>V,I,W<PMT>
Response:
Header on: :FETCH<space>V<space><NR2>,I<space><NR2>,W<space><NR2><RMT>
Header off: <NR2>,<NR2>,<NR2><RMT>
Separator 0: <NR2>
,<NR2>,<NR2><RMT>
Separator 1: <NR2>
;<NR2>;<NR2><RMT>
FETCh [ : SCALar ] : CURRent : RMS?
MEASure [ : SCALar ] : CURRent : RMS? 66201 | 66202
Description: These queries return the r.m.s. current.
Setting Syntax:
none
Setting Parameters: none
Query Syntax: FETCh:CURRent:RMS?<PMT> , MEASure:CURRent:RMS?<PMT>
Response Parameters: <NR2>
Header on: :FETCH:CURRENT:RMS<space><NR2><RMT>
Header off: <NR2><RMT>
Example: none
FETCh [ : SCALar ] : CURRent : PEAK+?
MEASure [ : SCALar ] : CURRent : PEAK+? 66201 | 66202
Description: These queries return the plus value of peak current.
Setting Syntax: none
Setting Parameters: none
Query Syntax: FETCh: CURRent:PEAK+?<PMT> , MEASure:CURRent:PEAK+?<PMT>
Response Parameters: <NR2>
Header on: :FETCH:CURRENT:PEAK+<space><NR2><RMT>
Header off: <NR2><RMT>
Example: none
FETCh [ : SCALar ] : CURRent : PEAK-?
MEASure [ : SCALar ] : CURRent : PEAK-? 66201 | 66202
Description:
These queries return the minus value of peak current.
Setting Syntax:
none
Setting Parameters: none
Query Syntax: FETCh:CURRent:PEAK-?<PMT> , MEASure:CURRent:PEAK-?<PMT>
Response Parameters: <NR2>
Header on: :FETCH:CURRENT:PEAK-<space><NR2><RMT>
Header off: <NR2><RMT>
Example: none
FETCh [ : SCALar ] : CURRent : INRush?
MEASure [ : SCALar ] : CURRent : INRush? 66202
Description: These queries return the inrush current.
Setting Syntax: none
5-16