38—TORQUE-FLITE TRANSMISSION
CHRYSLER SERVICE MANUAL
CONTROL CABLE HOUSING
THROTTLE CONTROL
ROD
Fig.
26—Illuminating Lamp Bulb Installation-
Imperial Models
MANUAL CONTROL CABLE
[56x675
Fig.
27—Releasing Manual Control Cable Spring Lock
Using Tool C-3399, remove bulb.
NOTE:
If
Tool C-3399
is not
available, remove
as many push buttons as are necessary
for
clear-
ance,
then, using
a
piece
of
cloth
(to
protect
fingers in case
of
bulb breakage) remove
the
bulb.
Replace face plate
and
bezel
and
test opera-
tion
of
unit.
On Imperial models,
the
bulb
and
socket
are
positioned
in
the
light conductor,
as
shown
in
Figure 26.
It is
necessary, therefore,
to
reach
behind
the
instrument panel
to
remove
the
bulb
and
socket. After replacing bulb, snap
socket into light conductor
as
shown
in
Figure
26.
20.
REPLACING BACK-UP LIGHT SWITCH
AND STARTER SWITCH
The back-up light switch
is
mounted
on the
left side
of
the
push button housing. Remove
housing,
as
outlined
in
Paragraph
18. Use
a
long, narrow-blade screwdriver
to
straighten
the four tabs that hold
the
switch. Place
re-
placement switch
in
position
on
housing
and
bend over
the
four tabs. Replace housing,
as
outlined
in
Paragraph
18.
To replace
the
starter switch, first remove
housing,
as
outlined
in
Paragraph 18. Drill
out
the two rivets holding
the
switch
to the
flange.
The switch replacement
kit
consists
of the
switch
and two
soft tubular rivets. Install
switch
on
flange
and
check clearance between
end
of N
(neutral) push button slide
and end
of switch plunger. Bend
the
flange,
on
which
switch
is
mounted,
to
obtain
.010
to
.015 inch
clearance. Reinstall housing
as
outlined
in
Paragraph
18.
21.
REMOVAL AND INSTALLATION
OF
CONTROL CABLE (TRANSMISSION END)
a. Removal
Engage the
1
(low) button to place cable adapt-
er spring lock
in
line with control cable adapter
plug hold
in
transmission case.
Remove cable adjustable mounting bracket
on transmission. Remove cable adapter housing
plug, insert screwdriver through hole. While
exerting pressure against cable lock, spring,
withdraw cable
as
shown
in
Figure
27.
b.
Installation
Remove neutral starting switch (Fig. 22) from
transmission case. Place manual valve lever
in
LOW detent. Hold the R (reverse) push button
in
at
full travel. Insert cable assembly into
its
adapter
in
the
control cable housing engaging
groove
in
cable
end
with lock spring. Move
ca-
ble
in and
out
to
make certain cable
is
securely
locked
in
lock spring. Adjust cable!
MyMopar.com