M-Series Manual Sub Control Panel and Its Functions
1) MAIN CONTROL SWITCH:
Auto: (left position) Machine will operate from the systems preconfigured program using the
rotary switch control located on the outside front cover.
Off: (center position) Power to all systems will be off and burner, pump and agitator will stop.
Manual: (right position) Main rotary switch on front cover is no longer active. The three switches
below for temperature control, pump and agitator must be used to control the melter’s operations.
2) TEMPERATURE CONTROLLER ON / OFF SWITCH: When this switch is on, the three digital controllers
to the right will be energized and they will be controlling the diesel burner and activate the hydraulics for
agitator motor, sealant material pump and the heated hose.
3) MATERIAL PUMP SWITCH:
Seal (Forward): When the switch is on “SEAL (Forward)” the pump will be rotating counter clockwise
with sealant material recirculating back to sealant material tank or to the application wand.
Off: When the switch is “OFF”, the pump will not be rotating.
Clean-out (Reverse): When the switch is on “CLEAN-OUT”, the pump will be rotating clockwise in
reverse direction and will be drawing back any sealant material in the application wand and plumbing
system back to the sealant material tank.
4) AGITATOR CCW / OFF / CW SWITCH: This switch controls the rotation of the agitator from counter-
clockwise (CCW) or clockwise (CW). If the switch is in the center position, the agitator will not rotate.
5) SEALANT TEMPERATURE CONTROLLER: The control system on your CIMLINE melter has been
factory set to run the most common types of sealant materials. See page 19 to override or change
settings.
6) PUMP LIGHT (Green): This LED light indicates that the sealant material has reached the preset
temperature and if the unit is running in the auto mode, the hydraulic circuit for the sealant material pump
will be activated. If enough sealant material has melted the pump should be turning and sealant material
should be circulating through the system and back into the top of the sealant material tank.
7) HEAT TRANSFER OIL CONTROLLER: The control system on you CIMLINE melter has been factory
set to not exceed the OEM heat transfer oil limits for maximum temperature. It is advised to only use heat
transfer oil from CIMLINE. See Page 21 for heat transfer oil information and specifications.
8) AGITATOR READY LIGHT (Green): This LED light indicates that the heat transfer oil has reached
the preset temperature and if the unit is running in the auto mode, the hydraulic circuit for the agitator will
be activated. If enough sealant material has melted the agitator should be turning.
9) HOSE TEMPERATURE CONTROLLER: The control system on your CIMLINE melter has been factory
set to run a heated hose to the proper temperature for successful application of sealant material.
10) HOSE READY LIGHT (Green): This LED light indicates that the heated hose has reached the
preset temperature and is ready to use.
11) DIESEL BURNER LIGHT (Yellow): This LED light indicates that the material and heat transfer oil
temperature control are demanding that the diesel burner circuit is turned on.
12) HEATED HOSE FUSE: This is a 240V/18A slow-blow fuse for protecting the heated hose.
13) HEATED HOSE GENERATOR LIGHT (Yellow): This LED light indicates that the heated hose
temperature control is demanding that the generator circuit is turned on.
14) LOW FLOW SWITCH: Some sealants dispense best at low flow rates (<4 on the flow controller). If
the sealant material dispenses unevenly, switch the AUTO/MANUAL switch to MANUAL and place the
low flow switch on “FOR MATERIAL FLOW LOWER THAN 4”. This will make the sealant material pump
only rotate when the wand trigger is pressed, resulting in a smoother, more consistent flow.
CIMLINE recommends using the Main Control Panel in “AUTO”
control mode. “MANUAL” mode is provided for trouble shooting
and trained advanced/experienced users.
NOTICE