EasyManua.ls Logo

Cisco ASR 9001 - AC Electrical Specifications

Cisco ASR 9001
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ValueDescription
70 dB at 80.6°F (27°C) maximumAcoustic noise
Operating (halfsine): 21 in/sec (0.53 m/sec)
Nonoperating (trapezoidal pulse): 20 G, 52 in/sec
(1.32 m/sec)
G is a value of acceleration, where 1G equals
32.17 ft/sec2 (9.81 m/sec2).
Note
Shock
Operating: 0.35 Grms from 3 to 500 Hz
Grms is the root mean square value of
acceleration.
Note
Nonoperating: 1.0 Grms from 3 to 500 Hz
Vibration
AC Electrical Specifications
Table 23: AC Electrical Specifications
ValueDescription
Up to two AC power modules per systemPower modules per system
765 VA (volt-amps) per AC power supply(up to two
AC power supply modules per system)
Total AC input power
100240 VAC nominal (range: 90 to 264
VAC)220240 VAC (UK)
Rated input voltage
For each AC power supply
module.
Note
50/60 Hz nominal (range: 47 to 63 Hz)50/60 Hz (UK)Rated input line frequency
15 A maximum at 100 VAC13 A maximum at 220
to 240 VRMS (UK)
Input current rating
15 A North America and Japan; 10 A international;
13 A UK
Source AC service requirement
Power redundancy requirements vary, based on
system configuration (number and type of line cards,
etc). AC and DC powered systems are N+1 protected.
Redundancy
Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide
121
Technical Specifications
AC Electrical Specifications

Table of Contents

Other manuals for Cisco ASR 9001

Related product manuals