Chapter 3 Switch Installation
Installing and Removing SFP Modules
3-24
Catalyst 3560 Switch Hardware Installation Guide
78-16057-01
Table or Shelf Mounting
Follow these steps to install the switch on a table or shelf:
Step 1 Locate the adhesive strip with the rubber feet in the mounting-kit envelope. Attach
the four rubber feet on the bottom of the switch near the four corners.
Note Do not attach the rubber feet over the recessed screw holes on the bottom
of the switch.
Step 2 Place the switch on the table or shelf near an AC power source.
After the switch is mounted on the table, you need to do these tasks to complete
the installation:
Power on the switch. See the Powering On the Switch section on page 1-3.
Connect to a 10/100 port, and run Express Setup. See the Starting Express
Setup section on page 1-4.
Connect to the front-panel ports. See the Connecting to the 10/100 Ports
section on page 3-29 and the Connecting to SFP Modules section on
page 3-32 to complete the installation.
For configuration instructions about using the CLI setup program, go to
Appendix C, Configuring the Switch with the CLI-Based Setup Program.
Installing and Removing SFP Modules
These sections describe how to install and remove SFP modules. The modules are
inserted into the SFP module slots on the front of the Catalyst 3560 switches.
These field-replaceable modules provide uplink interfaces.
You can use any combination of SFP modules. Refer to the Catalyst 3560 release
notes for the list of SFP modules that the Catalyst 3560 switches support. Each
port must match the wave-length specifications on the other end of the cable, and