Chapter 8 Troubleshooting the GoQAM
136 4004834 Rev D
LCD
Description
Alarm
Level
Probable Cause Check and Correct
Input (1-4)
MPEG
Transport
error
Minor MPEG transport error indicator counter.
An error occurred in the header of the
MPEG packet
Check one or more
upstream devices
connected to the DVB
ASI input ports
Run the Doctor Report
to troubleshoot
network connectivity
issues
Contact Cisco Services
Input (1-4)
packets were
dumped
See also
Input (1-4)
FIFO overflow
Minor A FIFO overflow occurred and packet
data has been lost. This indicates one or
more of the following conditions:
Too many sessions defined from the
DNCS for the GoQAM
The data rate as defined from the
DNCS for the GoQAM session is too
low, which also means that the data
rate of the ASI input to the GoQAM is
too high
Hardware problem
Incorrect modulation mode
Reduce the data rate of
input to the GoQAM
by doing the
following:
Reducing the
amount of
incoming data
Reducing the
amount of data
added to the
stream
Increasing the
GoQAM
modulation mode
Run the Doctor Report
to troubleshoot
network connectivity
issues
Contact Cisco Services
Input (1-4)
PAT Update
Status
or
Minor
The PAT seen at one of the inputs
(1-4) on the GoQAM yields a version
number change indicating that the input
stream has changed.
If the GoQAM handles
the PAT, the alarm is
for information only
(Status) and will clear.
No user action
required.
If the GoQAM does
not handle the PAT
update, the alarm is
sent as a Minor alarm,
and does not clear.
You may need to
reboot the GoQAM to
re-acquire the input
stream.