Troubleshooting Alarm Messages
4004834 Rev D 137
LCD
Description
Alarm
Level
Probable Cause Check and Correct
Input (1-4)
PMT Update
Status
or
Minor
The PMT seen at one of the inputs
(1-4) on the GoQAM yields a version
number change indicating that the input
stream has changed.
If the GoQAM handles
the PMT, the alarm is
for information only
(Status) and will clear.
No user action
required.
If the GoQAM does
not handle the PMT
update, the alarm is
sent as a Minor alarm,
and does not clear. Yo
may need to reboot the
GoQAM to re-acquire
the input stream.
OUT (1-2)
FIFO overflow
Minor A FIFO overflow occurred and packet
data has been lost indicating one or more
of the following conditions:
Too many sessions defined from the
DNCS for the GoQAM
The data rate as defined from the
DNCS for the GoQAM session is too
low, which also means that the data
rate of the ASI input to the GoQAM is
too high
Hardware problem
Incorrect modulation mode
Reduce the data rate of
input to the GoQAM
by doing one of the
following:
Reducing the
amount of
incoming data
Reducing the
amount of data
added to the
stream
Increasing the
GoQAM
modulator mode