EasyManua.ls Logo

Cisco III - Supervisor Engine III - Dhcp_Snooping-5; DIAG Messages; Diag-3

Cisco III - Supervisor Engine III
368 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-101
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
OL-11469-02
Chapter 2 Messages and Recovery Procedures
DIAG Messages
DHCP_SNOOPING-5
Error Message %DHCP_SNOOPING-5-DHCP_SNOOPING_MATCH_MAC_FAIL: [chars] drop message
because the chaddr doesn’t match source mac, message type: [chars], chaddr:
[enet], MAC sa: [enet]
Explanation
DHCP snooping enables match-source-mac validation and the check has failed. There
maybe a malicious host trying to carry out a DOS attack on the DHCP server.
Recommended Action No action is required. This message is for informational purposes only.
Error Message %DHCP_SNOOPING-5-DHCP_SNOOPING_NONZERO_GIADDR: [chars] drop message
with non-zero giaddr or option82 value on untrusted port, message type: [chars],
MAC sa: [enet]
Explanation
DHCP snooping discovers a DHCP packet with an option value that is not allowed on
an untrusted port. A malicious host may be trying to act as a DHCP relay or server.
Recommended Action No action is required. This message is for informational purposes only.
Error Message %DHCP_SNOOPING-5-DHCP_SNOOPING_UNTRUSTED_PORT: [chars] drop message
on untrusted port, message type: [chars], MAC sa: [enet]
Explanation
DHCP snooping discovers a DHCP packet with an option value that is not allowed on
an untrusted port. A malicious host may be trying to act as a DHCP relay or server.
Recommended Action No action is required. This message is for informational purposes only.
DIAG Messages
This section contains Online Diagnostics (DIAG) messages.
DIAG-3
Error Message %DIAG-3-ALWAYS_ENABLE_TEST: [chars]: The users are not allow to
disable monitoring for Test #[dec]
Explanation
The specified health monitoring test cannot be disabled.
Recommended Action No action is required. The system is working properly.
Error Message %DIAG-3-FIXED_INTERVAL_TEST: [chars]: The users are not allow to
change monitoring interval of Test #[dec]
Explanation
The specified health monitoring test interval cannot be changed.
Recommended Action No action is required. The system is working properly.