2-237
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
OL-11469-02
Chapter 2 Messages and Recovery Procedures
SIPSPA Messages
Error Message %SIP600_QOS-3-QUPDATE: SIP-600 Update Queue Hardware Failed - [chars]:
[chars] [dec] Cause: [hex]
Explanation
The SIP 600 received an error on the specified hardware queue when attempting the
specified action. This condition is the result of attempting to configure a QoS action.
Recommended Action There are a variety of reasons that this condition occurs: 1) If the user
configuration action was to remove a service policy and then reapply a service policy to the same
interface, it is possible that queues are still draining, which prevents new queues from being
allocated. You need to remove the service-policy that failed, wait for a period of time, and then
reapply the service policy. 2) It is possible that the number of resources has been depleted. You can
consolidate your current QoS configuration to free up resources and then try reapplying your new
configuration. 3) If the error was the result of removing queue hardware, then there is a hardware
problem that must be reported. If the problem persists, copy the message exactly as it appears on the
console or in the system log. Research and attempt to resolve the issue using the tools and utilities
provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply
clarifying information. Search for resolved software issues using the Bug Toolkit at
http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the
Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or
contact your Cisco technical support representative and provide the representative with the
information you have gathered. Attach the following information to your case in nonzipped,
plain-text (.txt) format: the output of the show logging and show tech-support commands and your
pertinent troubleshooting logs.
Error Message %SIP600_QOS-3-QWREDGTQLIMIT: SIP-600 WRED maximum threshold exceeds
queue-limit for queue [dec]
Explanation
The WRED maximum threshold values should be greater than the assigned queue limit.
This condition is the result of the user attempting to configure WRED or changing bandwidth rates,
which changes queue-limit values. If this error has occurred, the queue is allocated but WRED is not
enabled.
Recommended Action Make sure the queue-limits configured does not exceed any of the WRED
max_threshold values. If the queue-limit command is not configured, configure one that is greater
than WRED max_threshold values.
SIPSPA Messages
This section contains SPA messages on GSR line cards (SIPSPA).
SIPSPA-4
Error Message %SIPSPA-4-MAX_BANDWIDTH_NS: Total SPA bandwidth exceeds line card
capacity, full utilization of installed SPA interfaces is not supported
Explanation
The total bandwidth of the SPAs exceeds the rated capacity of this line card.
Recommended Action Refer to the line card guidelines for the maximum allowed aggregated SPA
bandwidth for the line card.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco III - Supervisor Engine III and is the answer not in the manual?

Cisco III - Supervisor Engine III Specifications

General IconGeneral
BrandCisco
ModelIII - Supervisor Engine III
CategorySoftware
LanguageEnglish

Related product manuals