Chapter 2 Messages and Recovery Procedures
OIR Messages
Error Message %OIR-6-PWRFAILURE: Module [dec] is being disabled due to power
convertor failure [hex]
Explanation
The DC-DC power convertor failed on the specified module. Replace the failed
hardware.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the
Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or
contact your Cisco technical support representative and provide the representative with the
information you have gathered. Attach the following information to your case in nonzipped,
plain-text (.txt) format: the output of the show logging and show tech-support commands and your
pertinent troubleshooting logs.
Error Message %OIR-6-REMFAN: Fan [dec] removed
Explanation
The OIR facility detected the removal of a fan tray.
Recommended Action No action is required.
Error Message %OIR-6-SEQ_MISMATCH: SCP seq mismatch for card in slot [dec] : [chars]
Explanation
The OIR facility detected an SCP sequence mismatch for the module in the specified
slot.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the
Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or
contact your Cisco technical support representative and provide the representative with the
information you have gathered. Attach the following information to your case in nonzipped,
plain-text (.txt) format: the output of the show logging and show tech-support commands and your
pertinent troubleshooting logs.
Error Message %OIR-6-STDBY_INSCARD: Standby was notified, card online in slot [dec]
Explanation
The OIR facility on the redundant supervisor engine was notified by the active
supervisor engine that a processor was inserted in the specified slot. All interfaces are usable now.
Recommended Action No action is required.