EasyManua.ls Logo

Cisco ME 3400 - Page 579

Cisco ME 3400
950 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-551
Cisco ME 3400 Ethernet Access Switch Command Reference
OL-9640-10
Chapter 2 Cisco ME 3400 Ethernet Access Switch Cisco IOS Commands
show policer cpu uni-eni
Examples This is an example of output from the show policer cpu uni-eni drop command.
Switch# show policer cpu uni-eni drop
=========================================
Port In Dropped
Name Frames Frames
Fa0/1 300 0
Fa0/2 0 0
Fa0/3 0 0
Fa0/4 0 0
Fa0/5 200 0
Fa0/6 0 0
Fa0/7 0 0
Fa0/8 0 0
Fa0/9 508055 325086
Fa0/10 0 0
Fa0/11 0 0
Fa0/12 0 0
Fa0/13 0 0
Fa0/14 0 0
Fa0/15 0 0
Fa0/16 0 0
Fa0/17 0 0
Fa0/18 0 0
Fa0/19 0 0
Fa0/20 0 0
Fa0/21 0 0
Fa0/22 0 0
Fa0/23 0 0
Fa0/24 0 0
Gi0/1 0 0
Gi0/2 0 0
drop-all 0 1849645
This is an example of the new output format for the show policer cpu uni-eni drop interface command:
Switch# show policer cpu uni-eni drop interface gigabitethernet 0/1
============================
Policer assigned for Gi0/2
============================
Protocols using this policer:
"VTP" "CISCO_L2" "KEEPALIVE" "SWITCH_IGMP" "SWITCH_L2PT"
Policer rate: 160000 bps
In frames: 48014
Drop frames: 28630
This is an example of output from the show policer cpu uni-eni rate command when the default rate is
used.
Switch> show policer cpu uni-eni rate
CPU UNI/ENI port police rate = 160000 bps
This is an example of the show command output when CPU protection is disabled.
Switch# show policer cpu uni-eni rate
CPU Protection feature is not enabled

Table of Contents