4-6
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-06
Chapter 4 Installing a Cisco Nexus 7018 Chassis
Installing the Bottom-Support Rails on the Rack
Figure 4-1 Positioning the Bottom-Support Rails
Step 2 Use a Phillips screwdriver to screw in at least three (four if possible) M6 x 19 mm or 12-24 x 3/4 inch
Phillips screws on each end of each rail (using a total of 16 screws for both brackets) as shown in
Figure 4-2.
1 For the first and heaviest chassis installed in a
rack, position two bottom-support rails at the
lowest RU on the rack.
2 Allow at least 43.75 inches (111.1 cm)
(25 RU) for each Cisco Nexus 7018 system.