7-33
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-06
Chapter 7 Managing the Switch Hardware
Information About Fan Trays
SNMP notifications are sent (if configured).
To display the fan module statuses, use the show environment fan command as shown in Example 7-8
(Cisco Nexus 7009 switch), Example 7-9 (Cisco Nexus 7010 switch), or Example 7-10 (Cisco Nexus
7018 switch).
Example 7-8 Displaying Fan Information for a Cisco Nexus 7009 Series Chassis
switch# show environment fan
Fan:
----------------------------------------------
Fan Model Hw Status
----------------------------------------------
Fan1(sys_fan1) N7K-C700-FAN 0.31 Ok
Fan_in_PS1 -- -- Ok
Fan_in_PS2 -- -- Ok
Fan Air Filter:Absent
switch#
Example 7-9 Displaying Fan Information for a Cisco Nexus 7010 Series Chassis
switch# show environment fan
Fan:
------------------------------------------------------
Fan Model Hw Status
------------------------------------------------------
ChassisFan1 N7K-C7010-FAN-S 0.410 Ok
ChassisFan2 N7K-C7010-FAN-S 0.410 Ok
ChassisFan3 N7K-C7010-FAN-F 0.209 Ok
ChassisFan4 N7K-C7010-FAN-F 0.209 Ok
Fan_in_PS1 -- -- Ok
Fan_in_PS2 -- -- Ok
Fan_in_PS3 -- -- Ok
Fan Air Filter : Absent
switch#
Example 7-10 Displaying Fan Information for a Cisco Nexus 7018 Series Chassis
switch# show environment fan
Fan:
------------------------------------------------------
Fan Model Hw Status
------------------------------------------------------
Fan1(sys_fan1) N7K-C7018-FAN 0.204 Ok
Fan2(sys_fan2) N7K-C7018-FAN 0.204 Ok
Fan_in_PS1 -- -- Ok
Fan_in_PS2 -- -- Ok
Fan_in_PS3 -- -- Absent
Fan_in_PS4 -- -- Absent
Fan Air Filter : Absent
switch#
The possible Status field values are as follows:
If the fan module is operating properly, the status is Ok.
If the fan is physically absent, the status is Absent.