Send document comments to nexus7k-docfeedback@cisco.com
9-31
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-06
Chapter 9      Replacement Procedures
Replacing a Cisco Nexus 7009 Fabric Module During Operations
Step 14 With one or both hands on the front of the module, push the module all the way into the slot until it seats 
on the midplane connector.
Step 15 Simultaneously push both ejector levers inward until they come in contact with the face of the module. 
Note Verify that the ejector levers are fully closed before tightening the captive screws. Failure to fully seat 
the module in the backplane connector can result in error messages.
Step 16 Tighten the two captive screws on the I/O module to 8 in-lb (0.9 N·m).
Step 17 Reconnect the I/O cables to the ports or the transceivers on the fiber-optic cables to the ports on the 
module.
Replacing a Cisco Nexus 7009 Fabric Module During Operations
The Cisco Nexus 7009 switch has up five fabric modules located on the front of the chassis. You can 
replace one of these fabric modules at a time while the switch is operating. 
You should replace a fabric module with another fabric module within a couple minutes to maintain the 
designed system airflow. If you cannot replace the fabric module, you must fill the slot with a blank 
module.
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution 
when servicing. 
Statement 1034
Caution Make sure that you wear an ESD wrist strap while you handle each fabric module. Hold the module only 
on its carrier edges without touching any electronic circuitry, and place it on antistatic mats or repack it 
in its original packing materials when it is not installed in the chassis. 
To replace a fabric module, follow these steps:
Step 1 Place an antistatic mat or antistatic foam where you can place the fabric modules. Choose a place that 
prevents damage to the module while it is outside the chassis.
Step 2 Unpack and place the replacement fabric module on the antistatic mat or antistatic foam.
Step 3 Slide the eject button cover up and press the eject button. The ejector lever will pop out from the front 
of the fabric module.
Step 4 Rotate the ejector lever away from the front of the module and pull the module part way from the chassis. 
Step 5 Place your other hand under the module, fully pull the module from the chassis, and place the module 
on an antistatic surface.
Step 6 On the replacement module, if the ejector lever is placed against the front of the module, slide the eject 
button cover up, press the eject button, and fully rotate the ejector lever away from the front of the 
module. 
Step 7 Pick up the module with one hand under the module and the other holding the front of the module.