Full Redundancy
Mode
Input Source
Redundancy
Mode
Power Supply
Redundancy
Mode
Combined ModePower SuppliesPower Inputs
———3500 W11 input (277 V)
3500 W3500 W3500 W7000 W2
3500 W3500 W7000 W10,500 W3
7000 W7000 W10,500 W14,000 W4
—
——3500 W11 input (220/230
V)
3500 W3500 W3500 W7000 W2
3500 W3500 W7000 W10,500 W3
7000 W7000 W10,500 W14,000 W4
—
——3100 W11 input (210 V)
3100 W3100 W3100 W6200 W2
3100 W3100 W6200 W9300 W3
6200 W6200 W9300 W12,400 W4
—
——1500 W11 input (110 V)
1500 W1500 W1500 W3000 W2
1500 W1500 W3000 W4500 W3
3000 W3000 W4500 W6000 W4
A combination of 3-kW AC and 3.5-kW HVAC/HVDC power supplies can be used.
Note
Maximum Power Available for 3.5-kW Inputs (DC)
The maximum power available for operations depends on the input power from your power source, the number
and output capabilities of your power supplies, and the power redundancy mode that you use. The following
table lists the amount of power available for 3.5-kW HVAC/HVDC power supplies depending on DC power
inputs, number of power supplies, and the mode used.
Cisco Nexus 7706 Hardware Installation Guide
117OL-31330-01
Switch Specifications
Maximum Power Available for 3.5-kW Inputs (DC)