EasyManua.ls Logo

Cisco Nexus 7706 - 10-Gb SFP+ Optical Transceivers and Fabric Extender Transceivers

Cisco Nexus 7706
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Transmit and
Receive Wavelength
(nm)
Receive Power
(dBm)
Transmit Power
(dBm)
Transceiver TypeTransceiver
Four lanes: 1271,
1291, 1311, 1331
2.3 (maximum per
lane)
-13.7 (minimum per
lane)
2.3 (maximum per
lane)
-7 (minimum per
lane)
40GBASE-LR4QSFP-40G-LR4
840 to 860 nm2.4 (maximum per
lane)
-9.5 (minimum per
lane)
-1.0 (maximum per
lane*6)
-7.6 (minimum per
lane)
40GBASE-SR4QSFP-40G-SR4
832 to 9185 (maximum per
lane)
-6 (minimum per
lane)
5 (maximum per
lane)
-4 (minimum per
lane)
40GBASE-SR-BiDiQSFP-40G-SR-BD
Four lanes: 1271,
1291, 1311, 1331
2.3 (maximum per
lane)
-13.7 (minimum per
lane)
2.3 (maximum per
lane)
-10 (minimum per
lane)
40GBASE-LR4-LiteWSP-Q40G-LR4L
For the environmental specifications, see the following table.
SpecificationParameter
–40 to 185°F (–40 to 85°C)Storage temperature
32 to 104°F (0 to 40°C)Operating temperature
–40 to 158°F (–40 to 70°C)Case temperature
5 to 95 percentStorage relative humidity
10-Gb SFP+ Optical Transceivers and Fabric Extender Transceivers
The following table indicates which 10-Gigabit SFP+ transceivers are used with the 10-Gigabit Ethernet (GE)
I/O modules:
M3 Series 48-port 1-/10-GE
(N77-M348XP-23L)
F3 Series 48-port 1-/10-GE
(N77-F348XP-23)
F2 Series 48-Port
1-/10-GE
(N77-F248XP-23E)
Transceiver
CWDM-SFP10G-xxxx
X
DWDM-SFP10G-C
is not supported.
Note
X
DWDM-SFP10G-C
is not supported.
Note
X
DWDM-SFP10G-C
is not supported.
Note
DWDM-SFP10G-xx.xx
Cisco Nexus 7706 Hardware Installation Guide
OL-31330-01130
Switch Specifications
10-Gb SFP+ Optical Transceivers and Fabric Extender Transceivers

Table of Contents

Related product manuals