EasyManuals Logo

Cisco SG500-28P Administration Guide

Cisco SG500-28P
548 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #461 background imageLoading...
Page #461 background image
Security: Secure Sensitive Data Management
SSD Rules
443 Cisco 500 Series Stackable Managed Switch Administration Guide Release 1.3
23
- (Higher) Plaintext Only—Users are permitted to access sensitive data in
plaintext only. Users will also have read and write permission to SSD
parameters as well.
- (Highest) Both—Users have both encrypted and plaintext permissions
and are permitted to access sensitive data as encrypted and in
plaintext. Users will also have read and write permission to SSD
parameters as well.
Each management channel allows specific read permissions. The following
summarizes these.
Default Read Mode—All default read modes are subjected to the read
permission of the rule. The following options exist, but some might be
rejected, depending on the read permission. If the user-defined read
permission for a user is Exclude (for example), and the default read mode is
Encrypted, the user-defined read permission prevails.
- Exclude—Do not allow reading sensitive data.
- Encrypted—Sensitive data is presented in encrypted form.
- Plaintext—Sensitive data is presented in plaintext form.
Each management channel allows specific read presumptions. The
following summarizes these.
Table 1 Read Permissions Allowed per Management Channel
Management Channel Read Permission Options Allowed
Secure Both, Encrypted Only
Insecure Both, Encrypted Only
Secure XML SNMP Exclude, Plaintext Only
Insecure XML SNMP Exclude, Plaintext Only
Table 2 Default Read Modes for Read Permissions
Read Permission Default Read Mode Allowed
Exclude Exclude
Encrypted Only *Encrypted
Plaintext Only *Plaintext

Table of Contents

Other manuals for Cisco SG500-28P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG500-28P and is the answer not in the manual?

Cisco SG500-28P Specifications

General IconGeneral
Switching Capacity56 Gbps
Forwarding Rate41.67 Mpps
Flash Memory32 MB
Operating Humidity10% to 90% non-condensing
PoEYes
LayerLayer 2 and Layer 3
StackableYes
Power SupplyInternal
ManagementWeb-based GUI, CLI, SNMP
Jumbo Frame SupportYes
VLANs4096 VLANs
MAC Address Table Size16K entries
Dimensions440 x 44 x 350 mm
Operating Temperature0°C to 45°C
Ports28 (24 x 10/100/1000 PoE+ ports, 4 x 10/100/1000/SFP combo ports)