SNMP
Notification Recipients
525 Cisco 500 Series Stackable Managed Switch Administration Guide Release 1.3
26
Recipient IP Address/Name—Enter the IP address or server name of
where the traps are sent.
UDP Port—Enter the UDP port used for notifications on the recipient device.
Notification Type—Select whether to send Traps or Informs. If both are
required, two recipients must be created.
Timeout—Enter the number of seconds the device waits before re-sending
informs.
Retries—Enter the number of times that the device resends an inform
request.
Community String—Select from the pull-down the community string of the
trap manager. Community String names are generated from those listed in
the Community page.
Notification Version—Select the trap SNMP version.
Either SNMPv1 or SNMPv2 may be used as the version of traps, with only a
single version enabled at a time.
Notification Filter—Select to enable filtering the type of SNMP notifications
sent to the management station. The filters are created in the Notification
Filter page.
Filter Name—Select the SNMP filter that defines the information contained
in traps (defined in the Notification Filter page).
STEP 4 Click Apply. The SNMP Notification Recipient settings are written to the Running
Configuration file.
Defining SNMPv3 Notification Recipients
To define a recipient in SNMPv3:
STEP 1 Click SNMP > Notification Recipients SNMPv3.
This page contains recipients for SNMPv3.
STEP 2 Click Add.
STEP 3 Enter the parameters.
Server Definition—Select whether to specify the remote log server by IP
address or name.

Table of Contents

Other manuals for Cisco SG500-28P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG500-28P and is the answer not in the manual?

Cisco SG500-28P Specifications

General IconGeneral
Switching Capacity56 Gbps
Forwarding Rate41.67 Mpps
Flash Memory32 MB
Operating Humidity10% to 90% non-condensing
PoEYes
LayerLayer 2 and Layer 3
StackableYes
Power SupplyInternal
ManagementWeb-based GUI, CLI, SNMP
Jumbo Frame SupportYes
VLANs4096 VLANs
MAC Address Table Size16K entries
Dimensions440 x 44 x 350 mm
Operating Temperature0°C to 45°C
Ports28 (24 x 10/100/1000 PoE+ ports, 4 x 10/100/1000/SFP combo ports)