5-15
Catalyst 3750 Switch Software Configuration Guide
78-16180-02
Chapter 5 Managing Switch Stacks
Understanding Switch Stacks
To debug a specific stack member, you can access it from the stack master by using the session
stack-member-number privileged EXEC command. The stack member number is appended to the system
prompt. For example,
Switch-2# is the prompt in privileged EXEC mode for stack member 2, and the
system prompt for the stack master is
Switch. Only the show and debug commands are available in a
CLI session to a specific stack member.
Switch Stack Configuration Scenarios
Table 5-2 provides switch stack configuration scenarios. Most of the scenarios assume at least two
switches are connected through their StackWise ports.
Table 5-2 Switch Stack Configuration Scenarios
Scenario Result
Stack master election
specifically determined
by existing stack masters
Connect two powered-on switch stacks
through the StackWise ports.
Only one of the two stack masters becomes the new
stack master. None of the other stack members
become the stack master.
Stack master election
specifically determined
by the stack member
priority value
1. Connect two switches through their
StackWise ports.
2. Use the switch stack-member-number
priority new-priority-number global
configuration command to set one stack
member with a higher member priority
value.
3. Restart both stack members at the same
time.
The stack member with the higher priority value is
elected stack master.
Stack master election
specifically determined
by the configuration file
Assuming that both stack members have the
same priority value:
1. Make sure that one stack member has a
default configuration and that the other
stack member has a saved (nondefault)
configuration file.
2. Restart both stack members at the same
time.
The stack member with the saved configuration file
is elected stack master.
Stack master election
specifically determined
by the cryptographic EMI
software
Assuming that all stack members have the
same priority value:
1. Make sure that one stack member has
the cryptographic EMI software
installed and that the other stack
member has the noncryptographic EMI
software installed.
2. Restart both stack members at the same
time.
The stack member with the cryptographic EMI
software is elected stack master.