Support
model
CT-S280
CT-S300
CT-S2000
CT-S4000
CT-S251
CT-D150/E351
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310II
CT-D151/E651
- 358 -
fn=11: Function 11 Setting Communication Conditions
GS ( E pL pH fn a d1...dk
[Code] <1D>H<28>H<45>H<pL><pH><fn><a><d1>...<dk>
[Range] 3(pL+pH×256)65535(0pL255, 0pH255)
fn=11
1a4 (Not changed in other than specified range)
48d57 (Not changed in other than specified range)
1k6
[Outline] [The specification which is common to the model]
Sets the communication conditions of serial interface specified by “a”.
• a=1: Setting baud rate
Baud Rate
d1
d2
d3
d4
d5
d6
1200
49(“1”)
50(“2”)
48(“0”)
48(“0”)
-
-
2400
50(“2”)
52(“4”)
48(“0”)
48(“0”)
-
-
4800
52(“4”)
56(“8”)
48(“0”)
48(“0”)
-
-
▲9600
57(“9”)
54(“6”)
48(“0”)
48(“0”)
-
-
19200
49(“1”)
57(“9”)
50(“2”)
48(“0”)
48(“0”)
-
38400
51(“3”)
56(“8”)
52(“4”)
48(“0”)
48(“0”)
-
●57600
53(“5”)
55(“7”)
54(“6”)
48(“0”)
48(“0”)
-
●115200
49(“1”)
49(“1”)
53(“5”)
50(“2”)
48(“0”)
48(“0”)
---support by CT-S280/CT-S281/CT-S2000/CT-S4000/CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/
CT-S310II/CT-S251/CT-D150/CT-E351
---support by
CT-S280/CT-S2000/CT-S4000/CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/CT-S310II/CT-S251/CT-D150/CT-E351/CT-D151/ CT-E651
* CT-P29x series does not support 115200bps.
---Default : CT-S300/CT-S310/CT-S2000(JPN/EUR)/CT-S4000(JPN/EUR)
---Default : CT-S280/CT-S281/CT-S2000(USA)/CT-S4000(USA)/CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/
CT-P29x series/CT-S310II/CT-S251/CT-D150/CT-E351/CT-D151/ CT-E651
• a=2: Setting to specified parity
d1
Parity Setting
48 (Default)
No parity
49
Odd parity
50
Even parity
• a=3: Setting to specified flow control
d1
Flow Control
48 (Default)
DSR/DTR
49
XON/XOFF
• a=4: Setting to specified data length
d1
Setting Data Length
55
7-bit length
56 (Default)
8-bit length
• Operates only in printer function setting mode.
• Which of dip SW or memory SW is used at initialization depends on “Selecting communication condition
setting” of dip SW1-1.

Table of Contents