MBF-40 SMR700/SMR800 PS REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
Cobham Wireless – Coverage Date: 28-Jan-16 www.cobham.com/wireless
Doc. No. 00046UM Rev. 2.1
Page | 11
2.2.4 F/O Cable Installation Guidelines
This product is equipped with Class 1 Lasers, as per definition in EN 60825-1.
CAUTION!!!
Un-terminated optical receptacles may emit laser radiation.
Do not stare into beam or view with optical instruments.
WARNINGS!!
Maximum input power should not exceed (zero) 0 dBm
Clean the Fibre connectors (receptacles and cables) before connecting.
See APPENDIX B – F/O CLEANING PROCEDURE for details on F/O
cleaning procedures.
Note the following:
• This procedure requires opening the repeater.
• Use angled APC connectors at 8deg angle over the complete link between the Repeater and OMU
• Use APC type ODF connections
• Required Fibre cable: single mode 9/125
• Cable length - determined by the Remote installation plan. When calculating the cable length,
take into account excess cable slack so as not to limit the insertion paths.