2.2.4 F/O Cable Installation Guidelines
This product is equipped with Class 1 Lasers, as per definition in EN 60825-1.
CAUTION!!!
Un-terminated optical receptacles may emit laser radiation.
Do not stare into beam or view with optical instruments.
WARNINGS!!
Maximum input power should not exceed (zero) 0 dBm
Clean the Fibre connectors (receptacles and cables) before connecting.
See APPENDIX B F/O CLEANING PROCEDURE for details on F/O
cleaning procedures.
Note the following:
This procedure requires opening the repeater.
Use angled APC connectors at 8deg angle over the complete link between the Repeater and OMU
Use APC type ODF connections
Required Fibre cable: single mode 9/125
Cable length - determined by the Remote installation plan. When calculating the cable length,
take into account excess cable slack so as not to limit the insertion paths.