98-175666-D Appendix F: Event messages F-9
List of events
08A03-0 ADM WARNING GX Core Module
power
The Power Good signal from the Core
Module is low. The issue can either be: -
Internal Core Module or internal cable
failure - Temperature of Core Module is
too high and it has been turned off (*) -
GMU has been manually switched off on
the front panel (*) (*) = Only on systems
with GMU.
08A04-0 ADM WARNING iDirect modem The BDU detected a warning/error in the
iDirect modem. Log into the modem for
more information. Info: 0x00000001:
Temperature error 0x00000002: Test
error 0x00000004: Fan error
08A05-0 ADM WARNING GX Core Module
heating
The GX core module heater is active. It
will automatically be cleared when the
core module reaches the operational
temperature level.
08B00-0 ADM INFO IoT med priority
msg rate
exceeded.
The message rate limit has been reached
for the medium priority queue. The
iothub client will pause transmission of
medium priority messages for a short
while.
08B01-0 ADM INFO IoT low priority
msg rate
exceeded.
The message rate limit has been reached
for the low priority queue. The iothub
client will pause transmission of low
priority messages for a short while.
08B02-0 ADM INFO Iothub disabled The iothub client has been disabled.
09000-0 KDM ERROR KDM 3V3 supply Internal 3V3 voltage supply error in the
KDM.
09001-0 KDM ERROR KDM 12V supply Internal 12V voltage supply error in the
KDM.
09002-0 KDM ERROR KDM display Display hardware error in the KDM.
09010-0 KDM ERROR KDM link/SW
version
Link to the KDM module could not be
established. Either the KDM board is
malfunctioning, or - if the system
software has just been updated - the
software is too old and is not compatible
with the KDM hardware.
0A080-0 Antenna ERROR EBUS loop
interrupted
EBUS communication error, loop
interrupted.
ID Module Type Description Explanation