98-175666-D Appendix F: Event messages F-8
List of events
08844-0 ADM WARNING BUC voltage out
of range
The BUC voltage is out of range.
08845-0 ADM WARNING LNB voltage out
of range
The LNB voltage is out of range. The LNB
might be switched off to protect the
power supply circuitry. Reactivate
satellite profile to try again, check LNB
cable and surroundings if the problem
persists.
08846-0 ADM WARNING AIM-O supply
voltage out of
range
Supply voltage measured at AIM-O is not
within expected range.
08847-0 ADM WARNING AIM-O Master
PLL lock
The AIMO master PLL has lost lock. Check
the input reference signal.
08848-0 ADM WARNING TX Calibration
missing
Tx calibration not performed.
08880-0 ADM WARNING WLAN
configuration
error
Configuration of WLAN module failed.
08881-0 ADM WARNING DHCP Client
address
An IP address was received from an
external DHCP server that overlaps
another VLAN. Traffic on these VLANs may
be unpredictable. Reconfigure the server
or IP settings of that VLAN.
08A00-0 ADM WARNING GX Core Module
fan
There is a problem with the Core Module
fan. Check/clean and replace if necessary.
08A01-0 ADM WARNING GX Core Module
heater
There is a problem with the Core Module
heater. Check and replace if necessary.
08A02-0 ADM WARNING GX Core Module
temperature
The Core Module temperature is out of
range. This may affect performance, and
the Core Module will be shut down if the
situation gets worse. If the "GX core
module heating" event is also present,
the internal heater is currently warming
up the unit to its operational
temperature.
ID Module Type Description Explanation
Table F-1: Event messages (Continued)