Installation
Block Up Converter Systems 6700/6900 series User Guide 55
Connecting the remote controller
The optional Remote Controller 6570 is connected to the
Auxiliary I/O connector on the redundancy controller using a
19-way cable.
To connect the remote controller:
1 Plug the 25-way D-type socket on the 19-way cable into
the BUC Interface connector on the rear of the remote
controller.
1 Plug the 19-way MS plug on the 19-way cable into the
Auxiliary I/O connector on the redundancy controller.
NOTE
Before connecting a Remote Controller 6570,
you should ensure that the serial address and
packet protocol in each BUC has been set up
correctly using a Hand-held Controller 6560, or
other serial device such as a PC. For more
information see the Hand-held and Remote
Controller 6560/6570 User Guide.