GE 300 LED-status indication
3.3/0518 33
Subscriber cards
IP-DSP-subscriber card G3-IP
IP-DSP-subscriber card to connect up to 8 IP subscribers via Ethernet (LAN/WAN). Up to 5 G3-IP cards
can be used in one Intercom Server GE 300. The card is available in the feature levels B, C, D and P. The
number of subscribers and the individual features can also be activated with a licence key.
DSP-subscriber card G3-GED
DSP-subscriber card to connect up to 4 digital subscribers via two wires each. Up to 5 G3-GED cards
can be used in one Intercom Server GE 300. One conversation per subscriber is simultaneously possi-
ble (non-blocking). The card is available in the feature levels B, C, D and P. The individual features can
be activated with a licence key.
DSP-subscriber card G3-GET
DSP-subscriber card to connect up to 4 analogue subscribers via four wires each. Up to 5 G3-GET cards
can be used in one Intercom Server GE 300. The licence L3-GET-DSP also makes DSP functions (see
data sheet) available for analogue intercom stations. The card is available in feature levels B, C, D and
P. The individual features and the support for DSP functions can be activated with a licence key.
DSP subscriber card G3-GET
LED status indication RUN
LED status indication “Subscriber” (S1 to S4)
LED-status Description
LED is blinking in a one
second rhythm
The card is working correctly
LED is permanently off No power, warm start or hardware fault
LED is permanently on Waiting for connection to the main processor (during initialisation)
LED is blinking fast Card in the wrong slot or during firmware download
LED is blinking in
rhythm definition error
“short - short - long“
Card with wrong hardware feature level inserted (e.g. card “G3-IP-4B” inserted in slot
which is configured for “G3-IP4C”)
LED-status Description
LED is permanently on A working Intercom station is connected.
LED is permanently off No Intercom station connected
LED is blinking Line fault
LED is flickering During data transmission