Service schedule: Fluid Force HPO (4000 Hour oil change)
The bulk oil temperature must not exceed 90°c. If the oil is working above this temperature, the oil life will be reduced.
Note: When changing recommended oil types it is advisable to flush the compressor.
Page 8
CompAir Hydrovane
Introduction
Preventative Maintenance Schedule Fluid Force HPO
Maintenance Actions and Manual
Reference
Inst.
Every
Day
Every
Week
Every
1000
hrs
Every
2000
hrs
Every
4000
hrs
Every
8000
hrs
Every
12000
hrs
Every
24000
hrs
Suitable sited
3 333333
Adequate ventilation
3 333333
Ambient temperature
333333333
Sufficient access
3
Clear of airborne contaminants
333333333
Torque electrical connections
3 33333
Check oil level at filler plug 1C
3 333333
Check correct drive rotation
33
Check for air leaks
3 333333
Check for oil leaks
3 333333
Check air filter 1C
33
Check power on load
3 33333
Check power off load
3 33333
Check oil temperature
333333333
Check RSU oil temperature 1B
333333333
Check servo pressure on load
3 3333333
Check servo pressure off load
3 3333333
Check motor cable glands secure
3 33333
Check motor for damage 1C
3 33333
Check motor for loose connections 1C
3 33333
Check motor cables and earth 1C
3 33333
Check motor for vibration
3 33333
Check perishable oil pipes
33 3
Check oil seal 1C
3333
Check drive media
3333
Check operation of non-return valve
3 33333
Check RSU temperature
333333333
Check starter contactors
33
Check motor insulation resistance
3
Clean air/oil radiator external 1C
3333333
Clean external dirt from motor 1C
33333333
Clean cabinet air filter 1C
33 3
Clean solenoids
3333333