Page 9
Introduction
Preventative Maintenance Schedule Fluid Force HPO
Maintenance Actions and Manual
Reference
Install
Every
Day
Every
Week
Every
1000
hrs
Every
2000
hrs
Every
4000
hrs
Every
8000
hrs
Every
12000
hrs
Every
24000
hrs
Clean external dirt from compressor
3333333
Clean oil return filter 2F
33333
Clean air filter 2A
33
Grease motor bearings (if applicable)
3
Change Fluid Force HPO oil 1C
3333
Change oil filter 2F
3333
Change air filter 2A
33333
Change cabinet filter 1C
33333
Change unloader valve seals 2B
33333
Change MPV seals 2G
33333
Change vacuum valve seals 2D
33333
Change oil filter strainers
33333
Change perishable oil pipes
33
Change thermal motor
33
Change drive media 2J
3
Change non-return filter
3
Change oil seal
3
Change pressure gauge
3
Replace motor bearings
3
Test vacuum valve 5
3 33333
Test minimum pressure valve 5
3 33333
Test air delivery 5
3 33333