Event Messages
D-11
2-Line LCD
C:_ I:_ Timeout Waiting for I/O
Terminal
[1105] CHL:_ ID:_ SCSI Target ALERT: Timeout Waiting for I/O to
Complete
Event Type
"Alert !Warning "Notification
What
Happens?
Drive-side SCSI target I/O timeout. Possible drive-side
cabling/termination and canister connection abnormal or drive
malfunctioning.
What to
Do?
Check drive-side cabling/termination/canister connections and hard
drive.
2-Line LCD
C:_ I:_ Parity Error
Terminal
[1106] CHL:_ ID:_ SCSI Target ALERT: SCSI Parity/CRC Error
Detected
Event Type
"Alert !Warning "Notification
What
Happens?
Drive-side SCSI channel parity or CRC error detected to the specified
hard drive.
What to
Do?
Check drive-side cable/termination or drive canister connection.
2-Line LCD
C:_ I:_ Data Overrun/Underrun
Terminal
[1107] CHL:_ ID:_ SCSI Target ALERT: Data Overrun/Underrun
Detected
Event Type
"Alert !Warning "Notification
What
Happens?
Drive-side SCSI target data overrun or underrun detected.
What to
Do?
Check drive-side cabling/termination/canister connections and hard
drive.
2-Line LCD
C:_ I:_ Invalid Data Received
Terminal
[1108] CHL:_ ID:_ SCSI Target ALERT: Invalid Status/Sense Data
Received (Sense_key Sense_code)
Event Type
"Alert !Warning "Notification
What
Happens?
Drive-side SCSI invalid status/sense data received from target
What to
Do?
Check cabling/termination/canister connections.
2-Line LCD
C:_ LIP(__) Detected
Terminal
[110F] CHL:_ LIP(__) Detected
Event Type
"Alert !Warning "Notification
What
Happens?
Fibre Loop LIP issued.
What to
Do?
Press [ESC] to clear the error message.