Infortrend
D-12
2-Line LCD
C:_ SCSI Drive Channel Notification: SCSI Bus Reset Issued
Terminal
[110f] CHL:_ SCSI Drive Channel Notification: SCSI Bus Reset Issued
Event Type
"Alert !Warning "Notification
What
Happens?
SCSI bus reset issued
What to
Do?
2-Line LCD
C:_ I:_ SCSI Target ALERT: Unexpected Drive Not Ready
Terminal
[1111] CHL:_ ID:_ SCSI Drive ALERT: CHL:_ ID:_ Clone Failed
Event Type
"Alert !Warning "Notification
What
Happens?
Drive installed does not respond with "Ready"
What to
Do?
Check hard drive and drive-side cabling/termination/canister
connections.
2-Line LCD
C:_ I:_ Drive HW Error
Terminal
[1112] CHL:_ ID:_ SCSI Drive ALERT: Drive HW Error (Sense_key
Sense_code)
Event Type
"Alert !Warning "Notification
What
Happens?
Drive-Side SCSI drive unrecoverable hardware error reported
What to
Do?
Replace hard drive and the rebuild may begin with a hot-spare or a
replacement drive
2-Line LCD
C=_ I=_ Bad Block Encountered
Terminal
[1113] CHL:_ ID:_ SCSI Drive ALERT: Bad Block Encountered -
Block_number (Sense_key Sense_code)
Event Type
"Alert !Warning "Notification
What
Happens?
Hard drive unrecoverable media error reported. A bad block is
encountered in the specified hard drive. The RAID controller will ask
the hard drive to retry.
What to
Do?
Press [ESC] to clear the message.
2-Line LCD
C=_ I=_ Unit Attention Received
Terminal
[1114] CHL:_ ID:_ SCSI Target ALERT: Unit Attention Received
(Sense_key Sense_code)
Event Type
"Alert !Warning "Notification
What
Happens?
Drive-side SCSI target unit attention received.
What to
Do?
Check hard drive and drive-side cabling/termination/canister
connections.

Table of Contents