Event Messages
D-13
2-Line LCD
C=_ I=_ Unexpected Sense Rec.
Terminal
[1115] CHL:_ ID:_ SCSI Drive ALERT: Unexpected Sense Received
(Sense_key Sense_code)
Event Type
"Alert !Warning "Notification
What
Happens?
Drive-side SCSI drive unexpected sense data received.
What to
Do?
Checking drive-side cabling/termination/drive canister connections.
This might result from a bad signal quality of poor connection, etc.
2-Line LCD
C=_ I=_ Block Reassign Failed
Terminal
[1116] CHL:_ ID:_ SCSI Drive ALERT: Block Reassignment Failed -
Block_number (Sense_key Sense_code)
Event Type
"Alert !Warning "Notification
What
Happens?
Drive-side block reassignment failed. Drive will be considered failed.
What to
Do?
Press [ESC] to clear this error message.
2-Line LCD
C=_ I=_ Block Success Reassign
Terminal
[1117] CHL:_ ID:_ SCSI Drive ALERT: Block Successfully Reassigned –
Block_number (Sense_key Sense_code)
Event Type
"Alert "Warning !Notification
What
Happens?
Bad blocks have been reassigned successfully
What to
Do?
Press [ESC] to clear this message.
2-Line LCD
CHL=_ ID=_ Aborted Command
Terminal
[1118] CHL:_ ID:_ SCSI Drive ALERT: Aborted Command (Sense_key
Sense_code)
Event Type
"Alert !Warning "Notification
What
Happens?
SCSI drive aborted command reported
What to
Do?
Press [ESC] to clear the error message.