5-10 l Maintenance
Cleaning the Aftercooler Coils (continued)
5 Clean the assembly using a mild soap and water. Let the assembly dry thoroughly
before installation.
NOTE: In cases of heavy volatiles, steam cleaning, pressure washing or the use of solvents, such as
acetone, may be necessary. Be sure to test a small area with the solvent you have selected to be
sure there is no adverse reaction.
6 Inspect the condition of the gasket. If it is damaged, replace the gasket.
7 Reassemble by repeating the steps in reverse order.
8 Connect the water supply line and return lines.
9 Open valves to return water to the system.
0
Draining the Volatile Drain
The volatile drain (if equipped) is located at the
back of the dryer.
1 Place a bucket or container below the
volatile drain valve at the back of the dryer.
2 Open the volatile drain valve. Liquid should
begin to drain.
3 All the valve to completely drain. This may
take a few minutes.
4 Close the drain valve.
5 Properly dispose of (in accordance with all regulations) the drained fluid.