Troublesho oti ng l 6-21
6
Troubleshooting
Dewpoint Troubleshooting
Under normal operating conditions, the dryer will produce dewpoints in the range
of -40 to -20° F {-40 to -29° C}. However, you may experience situations that pro-
duce undesirable results.
Problem
Dryer not producing
desired dewpoint.
Possible cause
Return air temperature exceeds 125°F
{52°C}.
Regeneration temperature is below nor-
mal setting.
Low regeneration air flow.
Leaks in process lines.
Contaminated desiccant due to off-
gassing, too long of a residence time or
drying temperature is too high for the
grade of material being processed.
Analog option board/sensor malfunction
Solution
Reduce the temperature of the cooling
water or increase the flow.
Check amperage of regeneration heaters.
Replace heaters if necessary.
Check regeneration filter and clean
and/or replace as necessary.
Check all hoses, gaskets, doors, loaders
or other potential areas where leakage
may occur. Replace any defective hoses
or gaskets.
Verify proper drying temperatures and
residence times. If off-gassing is a con-
dition of the material being processed,
contact Conair Parts at (800) 458 1960
for the addition of a volatile trap.
Verify dryer dewpoint readings with a
calibrated portable dewpoint meter.
Replace analog option board or sensor.
WARNING: Any electrical
checks should be performed by
a qualified electrician.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Conair MDCW Carousel Plus W25 and is the answer not in the manual?

Conair MDCW Carousel Plus W25 Specifications

General IconGeneral
BrandConair
ModelMDCW Carousel Plus W25
CategoryDryer
LanguageEnglish

Related product manuals