Page #22 background imageLoading...
Page #22 background image
MDCW Carousel Plus Dryer Options
Volatile trap (use only in conjunction with aftercooler) - The volatile trap is
recommended when drying materials that produce volitales that condense into
a waxy or oily residue and/or if the material contains excessive fines.
Precooler - The precooler reduces the temperature of air flow after the
desiccant wheel and before the process heater, enabling the dryer to control
temperatures at low setpoints (100 - 15F {38 - 6C}).
Filter check - The filter check sensor will activate a passive alarm when the
process filter is clogged or needs replaced.
Heater current monitor - The heater current monitor measures the total
amperage across both the process and regeneration heaters and the pre-deter-
mined power consumption values for the blowers and the control.
CFM monitor - The CFM monitor measures the cubic feet per minute of air
flow across the inlet/outlet of the process blower.
Dryer communications - Allows the dryer to be networked to industrial control
systems. DeviceNet is standard on all DC-2 models, alternate communications
are available.
2-10 l De scr ip ti on

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Conair MDCW Carousel Plus W25 and is the answer not in the manual?

Conair MDCW Carousel Plus W25 Specifications

General IconGeneral
BrandConair
ModelMDCW Carousel Plus W25
CategoryDryer
LanguageEnglish

Related product manuals