SETUP, PROC, PROC, PROC, PROCESS
TEMPERATURE RANGE screen 39. The
display will return to the default screen
from any place in the menu structure (with
the exception of the AUTOTUNE screens)
if nothing is done after 10 minutes.
Pressing the MENU button from any place
in the menu structure will return you to the
default screen.
Shows the regeneration air setpoint and
actual temperature. The setpoint can be
changed with the correct password.
NOTE: Lowering the regeneration setpoint
decreases the capacity of the dryer and nor-
mally is not recommended. Use the dewpoint
control function instead.
Shows the actual return air temperature
measured at the inlet to the process
blower. If the optional aftercooler flow
control is installed, a setpoint will be
displayed on this screen. The setpoint can
be changed with the correct password.
This screen shows the amount of time the
conveying blower will run. Based on the
position of the demand sensor in the mate-
rial receiver, this time may need to be
adjusted. The time should be set for the
time it takes to satisfy the demand sensor
+ 1 second. If the MDCW tries to load 3
consecutive times without satisfying the
demand signal, the dryer will display a
passive alarm.
Function
4-12 l Operati on
✐
Screen
SCREEN 3 (DEFAULT SCREEN)
(continued)
SCREEN 4
SCREEN 5
SCREEN 6
PROCESS TEMPERATURE
ACT 325°F SET 325°F
REGENERATION TEMP
ACT 350°F SET 350°F
RETURN AIR TEMP
ACT 100°F SET 100°F
Control Function Descriptions(continued)
MACHINE LOADER
LOAD TIME 10 SEC