EasyManua.ls Logo

Conair W Series - Additional Alarms

Conair W Series
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Additional Alarms
Along with the alarm indicators, you may encounter additional messages that
indicate a problem within the control.
Problem
Control Not Ready, Please
Check Alarm - Displayed
when the “Start button is
pushed during any active
alarm. (Passive or Shutdown)
Lost Comm w/ Ctrl Bd -
Indicates there is a problem in
the communication between
the control board and the dis-
play board.
Error ! Incorrect Firm
Version - Indicates a mismatch
of software between the dis-
play board and the control
board.
Possible cause
The dryer will continue to run if there is
a passive alarm, however it will not start
if there is a active alarm.
Loose or improperly connected wire.
Improper dip switch setup on control
board.
Defective display or control board.
The software revision of the display
board and control board are not
compatible.
Solution
Push the acknowledgement alarm button
to identify the alarm, and address it as
necessary.
Check wiring between control board and
display board.
Check dip switch setup on control board.
Replace boards as a set.
In most cases, both display and control
boards will need to be replaced as a set.
6-18 l Tr ou bl es ho ot in g

Table of Contents

Related product manuals