Checking for Proper Air Flow
This procedure is required on W 50 - 100 models if the phase detection option was
not ordered with the dryer.
CAUTION: If the air flow direction is incorrect due to improper phase connection,
material from the hopper can be pulled into the process heater, causing permanent
damage to this equipment.
1 Turn on the main power to the dryer. Make sure the dryer’s disconnect dial is
in the “ON” position. This powers up the control and the display lights will
illuminate.
2 Select the setpoint temperature by pressing the select category button
under the setpoint temperature display. Once selected, the number will
flash.
3 Set the drying temperature. Press the select category button under the set-
point value until it blinks then use the setpoint adjustment (+) or (-) buttons or
enter a low setpoint temperature (150ºF {66ºC}) on the numeric keypad and
then press enter.