EasyManua.ls Logo

Conair W Series - Process Heater Tube

Conair W Series
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troublesh oo ti ng l 6-31
6
Troubleshooting
Replacing the Heaters
Process Heater Tube
1
Stop the dryer, disconnect the power, and follow proper lockout
procedures.
2 Remove the plastic cover.
3 Disconnect the wiring
harnesses of the defective
process heater. Then
disconnect the hoses from
the top and bottom of the
heater tube.
4 Remove the clamp securing
the heater tube in place then
remove the heater tube from
the dryer.
5 Cut the insulation in a
straight line from end to end
then remove it from the old
heater tube.
6 Compare the markings on the
outside of the process heater
tube to ensure the new one has
the same voltage and kW
ratings as the original heater
tube.
7 Put the insulation on the new heater tube. Use duct tape to hold the seam
together.
8 Secure the new heater tube using the hose clamp removed in Step 4.
9 Connect the hoses to the top and the bottom of the process heater tube.
continued
Process
Heater
Insulation
Wires
Clamps
Central
When configured as a
central dryer, there is no
process heater in the sys-
tem. Therefore, replac-
ing the process heater is
not applicable.

Table of Contents